Dual Extruder Calibration

Dual Extruder Calibration

Description

Test method, error and reconfiguration of eeprom firmware. The method of alignment of extruders is based on achieving a uniform rupture in the union of the colors (directions +/- X, +/- Y) reconfiguring after each printing the parameters of eeprom (offset X, offset Y) by small variations decimals +/- until achieving a uniform rupture in the four directions with respect to the material deposited by Extruder 1. The described method must be done with the STL files "cruz extr1 and cruz extr2". The rest of pairs of STL files is for a visual test. https://youtu.be/kphUOP78PMI Método de prueba error y reconfiguracion de firmware eeprom. El método de alineación de extrusores esta basado en lograr una ruptura uniforme en la unión de los colores (direcciones +/-X, +/-Y) reconfigurando posterior a cada impresión los parámetros de eeprom (offset X, offset Y) por pequeñas variaciones decimales +/- hasta lograr una ruptura uniforme en las cuatro direcciones respecto al material depositado por el Extrusor 1 .He publicado varios pares de objetos para test, entre cuales el de "sistema de cruz" puede analizarse de manera física, comprobando fragilidad. El resto de archivos STL es para una prueba visual.